Differences of hemodynamic responses in patients undergoing endotracheal intubation with conventional laryngoscope compared to video laryngoscope

Author(s): Dani Maryndianto
DOI: 10.30867/gikes.v5i2.1541

Abstract

Background: In general anesthesia, to facilitate the intubation process, laryngoscopy is used, with various shapes and sizes and additional functions such as use of video cameras, but it also comes with risks, one of which is a cardiovascular response.

Objectives: To compare differences of hemodynamic responses (SBP= Systolic blood pressure, DBP= Siastolic blood pressure, HR= Heat rate, MAP= Mean atrial preassure, and RPP= Rate pressure product) in patients who undergoing endotracheal intubation with conventional laryngoscopes compared to video laryngoscopes at H. Adam Malik General Hospital.

Methods: This is an analytical study with a pretest-posttest controlled group clinical trial design to compare differences of hemodynamic response in patients undergoing endotracheal intubation with conventional laryngoscope compared to video laryngoscope. All patients who underwent elective surgery under general anesthesia and endotracheal intubation and met the inclusion and exclusion criteria were included in the study.

Results: This study showed a significant difference between the conventional laryngoscopy and video laryngoscopy groups on the results of systolic blood pressure measurements. While diastolic blood pressure at T0, T1, and T2 after laryngoscopy did not show significant differences. This significant difference was found at T1, where the HR of subjects in conventional laryngoscopy was significantly higher compared to video laryngoscopy.

Conclusion: The use of a conventional laryngoscope for laryngoscopy and endotracheal intubation further enhances hemodynamic response compared to video laryngoscope, both when the glottis is visualized and when the cuff is inflated.

Keywords

Laryngoscope, intubation, hemodynamics

Full Text:

PDF

References

Amini, S., & Shakib, M. (2015). Hemodynamic changes following endotracheal intubation in patients undergoing cesarean section with general anesthesia: application of glidescope® videolaryngoscope versus direct laryngoscope. Anesthesiology and Pain Medicine, 5(2), 21836. https://doi.org/10.5812/AAPM.21836

Barash, P., Cullen, B., Cahalan, M., & Stoelting, R. (2013). Acute pain management. In Clinical anesthesia (pp. 75–76). United States of America: Lippicontt williams and wilkins.

Beyer, K., Taffé, P., Halfon, P., Pittet, V., Pichard, S., Haller, G., & Burnand, B. (2009). Hypertension and intra-operative incidents: a multicentre study of 125,000 surgical procedures in Swiss hospitals. Anaesthesia, 64(5), 494–502. https://doi.org/10.1111/J.1365-2044.2008.05821.X

Buhari, F., & Selvaraj, V. (2016). Randomized controlled study comparing the hemodynamic response to laryngoscopy and endotracheal intubation with McCoy, Macintosh, and C-MAC laryngoscopes in adult patients. Journal of Anaesthesiology, Clinical Pharmacology, 32(4), 505. https://doi.org/10.4103/0970-9185.194766

Butterworth, J., Mackey, D., & Wasnick, J. (2015). Anesthesia for Neurosurgery. In Morgan & Mikhail’s Clinical Anesthesiology. 5th Edition (5th ed., pp. 593–594). New York: McGraw Hill.

Çakir, M., & Özyurt, E. (2020). Comparison of direct laryngoscope and McGrath videolaryngoscope in terms of glottic view and hemodynamics in bariatric surgery. Turkish Journal of Medical Sciences, 50(1), 213–218. https://doi.org/10.3906/SAG-1905-77

Colak, F., Ozgul, U., Erdogan, M. A., Kayhan, G. E., Erdil, F. A., Çolak, C., & Durmus, M. (2019). Comparison of hemodynamic responses and QTc intervals to tracheal intubation with the McGRATH MAC videolaryngoscope and the Macintosh direct laryngoscope in elderly patients. The Kaohsiung Journal of Medical Sciences, 35(2), 116–122. https://doi.org/10.1002/KJM2.12017

Dashti, M., Amini, S., Azarfarin, R., Totonchi, Z., & Hatami, M. (2014). Hemodynamic changes following endotracheal intubation with glidescope(®) video-laryngoscope in patients with untreated hypertension. Research in Cardiovascular Medicine, 3(2), 4. https://doi.org/10.5812/CARDIOVASCMED.17598

Gavrilovska-Brzanov, A., Jarallah, M. Al, Cogliati, A., Mojsova-Mijovska, M., Mijuskovic, D., & Slaveski, D. (2015). Evaluation of the hemodynamic response to endotracheal intubation comparing the airtraq(®) with macintosh laryngoscopes in cardiac surgical patients. Acta Informatica Medica : AIM : Journal of the Society for Medical Informatics of Bosnia & Herzegovina : Casopis Drustva Za Medicinsku Informatiku BiH, 23(5), 280–284. https://doi.org/10.5455/AIM.2015.23.280-284

Kanchi, M., Nair, H., Banakal, S., Murthy, K., & Murugesan, C. (2011). Haemodynamic response to endotracheal intubation in coronary artery disease: Direct versus video laryngoscopy. Indian Journal of Anaesthesia, 55(3), 260. https://doi.org/10.4103/0019-5049.82673

Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017). Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation: a cochrane systematic review. British Journal of Anaesthesia, 119(3), 369–383. https://doi.org/10.1093/BJA/AEX228

Liu, Z. J., Yi, J., Guo, W. J., Ma, C., & Huang, Y. G. (2016). Comparison of McGrath series 3 and macintosh laryngoscopes for tracheal intubation in patients with normal airway by inexperienced anesthetists: a randomized study. Medicine, 95(2). https://doi.org/10.1097/MD.0000000000002514

Marsaban, A., Heriwardito, A., & Yundha, I. (2017). Cardiovascular response and backward, upward, right push maneuver during laryngoscopy: comparison between CMAC® video laryngoscopy and conventional Macintosh. Med J Indones, 26(2), 116–21.

Sargin, M., & Uluer, M. S. (2016). Comparison of McGrath(®) series 5 video laryngoscope with macintosh laryngoscope: a prospective, randomised trial in patients with normal airways. Pakistan Journal of Medical Sciences, 32(4), 869–874. https://doi.org/10.12669/PJMS.324.10037

Urban, B. W., & Bleckwenn, M. (2002). Concepts and correlations relevant to general anaesthesia. British Journal of Anaesthesia, 89(1), 3–16. https://doi.org/10.1093/BJA/AEF164

Xue, F. S., Zhang, G. H., Li, X. Y., Sun, H. T., Li, P., Li, C. W., & Liu, K. P. (2007). Comparison of hemodynamic responses to orotracheal intubation with the GlideScope videolaryngoscope and the Macintosh direct laryngoscope. Journal of Clinical Anesthesia, 19(4), 245–250. https://doi.org/10.1016/J.JCLINANE.2006.11.004

Refbacks

  • There are currently no refbacks.